Vaportest Air Monitoring Badges are simple and effective devices that collect contaminants through the scientific principle of diffusion. They meet or exceed OSHA accuracy requirements of ±25% at 95% confidence level for many work contaminants.
Made from aplastic nylon that contains a permeable, absorbent membrane that can be lab tested containing Anasorb 747, 500 mg. Multiple substances can be sampled on a single badge at the same time, helping you assess the exposure level of the gases and vapours around you.
Exposure time: Anything from 15 minutes to 24 hours*
*Accurate exposure time must be recorded on the Analysis Request Form in order to be valid for analysis.
Specification
Housing Material | Nylon |
Sorbent | Anasorb 747, 500mg |
Conentration Range | Varies- dependent upon chemical of interest |
Analysis | Solvent desporation, gas chromatography/flame ionization detector (GC/FID) |
Shelf-life | 2 years from the date of manufacture at <39.2F (4 C) |
Storage | Before use: Store at ambient temperature or < 39.2 F (4 C). If storing at < 39.2 F(4 C), bring to ambient temperature before sampling. Note: Storage at < 39.2 F (4 C) is
|
Sample Time: | Validated for 15-min and 8-hr occupational exposure sampling. Lab and fi eld studies conducted with several compounds show suitability for 24-hr air sampling. |
Sampling Rate: | Dependent upon the chemical of interest. For compound-specific sampling rates. |
Dimensions | 1.4x 2.5 x 0.6 cm (3.5 x 6.3 x 1.5 inches) |